Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Muscle Nerve ; 58(2): 300-303, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29466828

RESUMO

INTRODUCTION: We describe a new nerve conduction study technique with reference values for the 3 branches of the supraclavicular nerve (SCN) in young healthy subjects and application of it in 2 patients. METHODS: The recording electrode was placed on the posterior border of the sternocleidomastoid muscle, 6-7 cm from the sternoclavicular joint. SCN branches were stimulated below the clavicle, 2.5, 7, and 10.5 cm lateral to the sternoclavicular joint. RESULTS: Twenty healthy volunteers (10 men), 19-38 years, mean 25.9 years (SD 6.3), and 2 patients with SCN lesions were studied. The mean conduction velocities of the SCN branches were 70-78 m/s (SD 8-10 m/s), and amplitudes 3-4 µV (SD 0.9-2.0 µV). There were no side-to-side or gender differences. DISCUSSION: The 3 SCN branches could be studied in all subjects. We provide reference values for young subjects. This new method was useful in verifying SCN lesions in 2 patients. Muscle Nerve 58: 300-303, 2018.


Assuntos
Condução Nervosa/fisiologia , Nervos Periféricos/fisiologia , Potenciais de Ação , Adulto , Estimulação Elétrica , Eletrodos , Eletromiografia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Neuralgia/patologia , Neuralgia/fisiopatologia , Exame Neurológico , Traumatismos dos Nervos Periféricos/patologia , Traumatismos dos Nervos Periféricos/fisiopatologia , Valores de Referência , Células Receptoras Sensoriais , Adulto Jovem
2.
J Back Musculoskelet Rehabil ; 30(6): 1319-1325, 2017 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-29154267

RESUMO

OBJECTIVE: To evaluate the test-retest reliability and validity of the MOCAP system for measuring spinal sagittal thoracic and lumbar curvatures and sacral inclination in a standing posture. METHODS: Twenty-five male adults were evaluated on lateral standing radiographs. The thoracic and lumbar curvatures were calculated by Harrison's posterior tangent method. The sacral inclination was defined as the angle between the tangent line of the sacral and vertical plane. In addition, MOCAP was used to calculate the spinal curvatures and sacral inclination. RESULTS: The thoracic and lumbar spine and sacral inclination demonstrated excellent reliability, with mean ICCs levels greater than 0.980 and low CVs (mean: 2.15%). Systematic biases were not significant and were very near 0, and the mean standard errors were 0.257∘. ANOVA of the radiographic and MOCAP measures did not report any statistically significant differences in the comparisons. The systematic biases and mean random errors were lower than 1∘, with CVs lower than 5% and mean ICCs higher than 0.90 between sessions. CONCLUSION: The MOCAP system delivered consistently reliable and valid results for standing curvatures compared with a radiographic technique. This system could be used with confidence in research and clinical environments for sagittal spinal curvature measurements.


Assuntos
Vértebras Lombares/fisiopatologia , Postura/fisiologia , Processamento de Sinais Assistido por Computador , Curvaturas da Coluna Vertebral/diagnóstico , Vértebras Torácicas/fisiopatologia , Humanos , Masculino , Reprodutibilidade dos Testes , Curvaturas da Coluna Vertebral/fisiopatologia , Adulto Jovem
3.
Artigo em Inglês | MEDLINE | ID: mdl-28946536

RESUMO

OBJECTIVE: To evaluate the test-retest reliability and validity of the MOCAP system for measuring spinal sagittal thoracic and lumbar curvatures and sacral inclination in a standing posture. METHODS: Twenty-five male adults were evaluated on lateral standing radiographs. The thoracic and lumbar curvatures were calculated by Harrison's posterior tangent method. The sacral inclination was defined as the angle between the tangent line of the sacral and vertical plane. In addition, MOCAP was used to calculate the spinal curvatures and sacral inclination. RESULTS: The thoracic and lumbar spine and sacral inclination demonstrated excellent reliability, with mean ICCs levels greater than 0.980 and low CVs (mean: 2.15%). Systematic biases were not significant and were very near 0, and the mean standard errors were 0.257∘. ANOVA of the radiographic and MOCAP measures did not report any statistically significant differences in the comparisons. The systematic biases and mean random errors were lower than 1∘, with CVs lower than 5% and mean ICCs higher than 0.90 between sessions. CONCLUSION: The MOCAP system delivered consistently reliable and valid results for standing curvatures compared with a radiographic technique. This system could be used with confidence in research and clinical environments for sagittal spinal curvature measurements.

4.
Muscle Nerve ; 53(3): 351-62, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26112058

RESUMO

INTRODUCTION: The aim of this study was to create reference values for jitter measured with concentric needle electrodes. METHODS: Operators worldwide contributed recordings from orbicularis oculi (OO), frontalis (FR), and extensor digitorum (ED) muscles in healthy controls. Criteria for acceptable signal quality were agreed upon in advance. Fifteen or 20 recordings of acceptable quality from each muscle were required for voluntary and electrical stimulation recordings, respectively. RESULTS: Recordings from 59 to 92 subjects were obtained for each muscle and activation type. Outlier limits for mean consecutive difference and individual jitter data for voluntary activation were: OO, 31 and 45 µs; FR, 28 and 38 µs; ED, 30 and 43 µs; and for electrical stimulation they were: OO, 27 and 36 µs; FR, 21 and 28 µs; ED, 24 and 35 µs. CONCLUSION: Reference jitter values from concentric needle electrode recordings were developed from signals of defined quality while seeking to avoid creating supernormal values.


Assuntos
Eletrodos , Potenciais Evocados/fisiologia , Músculo Esquelético/fisiologia , Junção Neuromuscular/fisiologia , Adulto , Biofísica , Estimulação Elétrica , Eletromiografia , Humanos , Pessoa de Meia-Idade , Valores de Referência , Estatística como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...